[Solutions] What Is The Reason & Solutions When Glass Come To Unloading Table of Glass Tempering Furnace And Can Not Stop Automatically?
After heating and cooling, the glass will be transferred to the unloading table section of glass tempering furnace, but sometimes the glass will not stop automatically when it comes to unloading table and falling off. If this problem happens, please check the following reasons: 1. The problem with t
Read More
[Solutions] How to maintain the main transmission system of of glass tempering furnace?
The main transmission mechanism of the glass tempering furnace is the core part of the equipment, and the smooth operation of the main transmission mechanism is the fundamental basis for producing high-quality tempered glass in the tempering furnace; 1. Regularly observe the lubricating oil level in
Read More
[Solutions] How to inspect the glass tempering furnace before starting work after the long holiday?
After long holiday, and before glass tempering furnace running, especially during winter, pls check below things: 1. Please first heat up or ventilate the workshop to remove moisture and avoid electrical faults caused by condensation water. 2. The ground must be cleaned thoroughly before removing an
Read More
[Solutions] What is the solution for thermocouple failure in glass tempering furnace without heating?
If the thermocouple of the glass tempering furnace malfunctions and does not heat up, the following treatment methods can be tried:1. Check the thermocouple connection: confirm whether the thermocouple connection is loose or detached. 2. If it is a connection issue, reconnect the thermocouple and en
Read More
[Solutions] How to replace the thermocouples of the glass tempering furnace?
1. Material preparationBefore replacing the lower thermocouple of the glass tempering furnace, the following tools and materials need to be prepared:1.1. Wrench1.2. Wire scissors1.3. Insulation tape1.4. Thermocouples1.5. Fuses1.6. Thermocouple instruction manual 2. Remove the old damaged thermocoupl
Read More
[Solutions] How to adjust the photoelectric switch on glass tempering furnace?
The photo sensor is installed at the loading table of glass tempering furnace.1. Adjust the position of the lower bracket of the photoelectric switch so that the receiving end of the photoelectric switch is basically aligned with the transmitting end.2. After connecting the 24V power supply to the p
Read More
[Solutions] What is the role of zebra crossing line onto unloading table of the glass tempering furnace?
For many glass tempering furnaces, we can see that a zebra crossing lines are painted on the cover of quenching section near to unloading table. But do you know the purpose of these zebra crossings? These zebra crossings are mainly used to observe the flatness of tempered glass after being tempered.
Read More
[Solutions] What are the main functions of the thermal balance system of the glass tempering furnace?
1. Ensure the temperature stability of the glass tempering furnace: The thermal balance system can ensure the stability of the temperature inside the heating furnace and avoid unstable heat treatment quality caused by excessive temperature fluctuations. 2. Improve the energy efficiency of glass temp
Read More