LV-TFBQ2436/36C flat/bent combination glass tempering furnace is a special plant used to produce the flat and bent tempered glass and thermal strengthened glass, which mainly used in the fields of architecture (doors, windows), garden fence, elevator, furniture, etc.
With force convection system, the Low-e glass could be processed, especially for soft (off-line) Low-e glass.
Availability: | |
---|---|
Quantity: | |
LV-TFB
LEVER
84752919
1. Supply Scope:
1.1. Loading table
1.2. Heating section with force convection system at the top of oven (Vesuvius ceramic roller)
1.3. Flat tempering & cooling section (2436)
1.4. Bent tempering & cooling section (36C)
1.5. Unloading table
1.6. Blower system (Taixin, Taiwan brand; Siemens or Schneider Blower Inverter)
1.7. Electrical & control system (Siemens PLC, Computer, etc)
1.8. Spare parts as listed in appendix
1.9. Technical documents
2. Basic parameters:
Max. glass size for flat tempered glass: 2440x3660mm
Min. Glass size for flat tempered glass: 150x280 mm
Glass thickness: 4-19mm
Max. Glass size for bent tempered glass: ⌒2440x3600mm
Min. Glass size for bent tempered glass: 150x280 mm
Glass thickness: 5-19mm
Min. Radius: R≥1000mm
Heating technology: Radiation + Force Convection System at top oven
Blower Quantity & Power: 250 kw X 1 set (Controlled by frequency inverter)
Finished product rate: ≥99.5% (5mm flat glass as sample)
3. Installation Power & Transformer Capacity
Heating Power: 580 kw
Quenching Power: 250 kw
Others: about 25 kw
Total: 855 kw
Transformer Capacity: ≥800 KVA
1. Supply Scope:
1.1. Loading table
1.2. Heating section with force convection system at the top of oven (Vesuvius ceramic roller)
1.3. Flat tempering & cooling section (2436)
1.4. Bent tempering & cooling section (36C)
1.5. Unloading table
1.6. Blower system (Taixin, Taiwan brand; Siemens or Schneider Blower Inverter)
1.7. Electrical & control system (Siemens PLC, Computer, etc)
1.8. Spare parts as listed in appendix
1.9. Technical documents
2. Basic parameters:
Max. glass size for flat tempered glass: 2440x3660mm
Min. Glass size for flat tempered glass: 150x280 mm
Glass thickness: 4-19mm
Max. Glass size for bent tempered glass: ⌒2440x3600mm
Min. Glass size for bent tempered glass: 150x280 mm
Glass thickness: 5-19mm
Min. Radius: R≥1000mm
Heating technology: Radiation + Force Convection System at top oven
Blower Quantity & Power: 250 kw X 1 set (Controlled by frequency inverter)
Finished product rate: ≥99.5% (5mm flat glass as sample)
3. Installation Power & Transformer Capacity
Heating Power: 580 kw
Quenching Power: 250 kw
Others: about 25 kw
Total: 855 kw
Transformer Capacity: ≥800 KVA